Low Frequency Hybrid Solar Inverter with On Grid or Off Grid Working Mode
Brand: ROYCE OEM Service: Yes Model: HF Input Voltage: 48vdc Output Voltage: 110V/120V/220V/230/V240VAC±2% Output Current: 22.7A~50A Protection: OverLoad/ Over Voltage/ short circuit Output waveform: Pure Sine Wave
The hybrid solar inverter is a multipurpose solar inverter that can operate seamlessly in three modes: off-grid, hybrid, and on-grid. Off-grid mode: You can directly power electrical equipment using solar energy or batteries when there is a shortage of utility electricity. In hybrid mode, batteries, solar energy, and a utility power source can all be used simultaneously. In the "on-grid" mode, solar-generated electricity can be profitably transmitted to the national utility system. In order to guarantee the safe and dependable operation of electrical equipment, in the event that the utility power supply is abruptly cut off, the system is capable of instantly switching to the generator power source.
Specifications:
Model: HF | 50248 | 60248 | 80248 | 10348 | 12348 | |
PV | Max PV Input Power | 6000W | 6000W | 4500W*2 | 6000W*2 | 6000W*2 |
MPPT Tracking Voltage Range | 120VDC-450VDC | |||||
Rated Voltage | 360VDC | |||||
Max PV Input Voltage Voc (at the lowest temperature) | 500VDC | |||||
Max PV Input Current | 27A | 18A*2 | 27A*2 | |||
MPPT Tracking Channels (Input Routed ) | 1 Routed | 2 Routed | ||||
Battery & Charging | Battery Type | Lead-acid Battery/Lithium Battery | ||||
Custom Battery (Charging and discharging parameters of different types of batteries can be set through the operation board) | ||||||
Rated Battery Voltage | 48VDC | |||||
Battery Voltage Range | 42~60VDC(default) | |||||
Max PV Charging Current | 120A | 150A | 180A | 200A | ||
Max AC Charging Current | 80A | 100A | 120A | 140A | ||
Max Charging Current | 120A | 150A | 180A | 200A | ||
On-Grid Operation | ||||||
On-Grid Output (AC) | Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW |
Rated Output Voltage | 220VAC/230VAC/240VAC | |||||
Grid Voltage Range | 187VAC~264VAC | |||||
Rated Output Frequency | 50Hz/60Hz | |||||
Frequency Range | 47Hz~52Hz(50Hz),57Hz~62Hz(60Hz) | |||||
Rated Output Current | 22.7A/21.7A/ | 27.3A/26.1A/ | 36.4A/34.8A/ | 45.5A/43.5A/ | 54.5A/52.2A/ | |
20.8A | 25A | 33.3A | 41.7A | 50A | ||
Power Factor | >0.98(Rated Power) | |||||
Off-Grid Operation | ||||||
AC Input | Rated Input Voltage | 220V/230V/240V | ||||
Mains input voltage range | 165VAC~280VAC / 120VAC~280VAC(Can be set) | |||||
Rated Input Frequency | 50Hz/60Hz | |||||
Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | |||||
AC Output | Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW |
Rated Output Voltage | 220V/230V/240V | |||||
Output Voltage Accuracy | ±2% | |||||
Rated Input Frequency | 50Hz/60Hz | |||||
Output Frequency Accuracy | ±1% | |||||
Output Wave | Pure Sine Wave | |||||
Hybrid Operation (Complementary Mode) | ||||||
AC Input | Rated Input Voltage | 220V/230V/240V | ||||
Mains Input Voltage Range | 187VAC~264VAC | |||||
Rated Input Frequency | 50Hz/60Hz | |||||
Input Frequency Range | 47Hz~52Hz(50Hz),57Hz~62Hz(60Hz) | |||||
AC Output | Rated Output Power | 5000W | 6000W | 8000W | 10KW | 12KW |
Rated Voltage | 220VAC/230VAC/240VAC | |||||
Rated Output Current | 22.7A/21.7A/20.8A | 27.3A/26.1A/25A | 36.4A/34.8A/33.3A | 45.5A/43.5A/41.7A | 54.5A/52.2A/50A | |
Regular Parameters | ||||||
Maximum Conversion Efficiency (Battery Discharge) | 94% (peak value) | |||||
MPPT Tracking Efficiency | ≥99.9 | |||||
Transfer Time | 10ms(Typical value) | |||||
Display | LCD+LED | |||||
Cooling Method | Cooling fan in intelligent control | |||||
Communication | RS485/Dry Contact/Mobile APP(WIFI Monitoring or GPRS monitoring)(Optional) | |||||
Protection Degree | IP20 | |||||
Installation | Wall-Mounted | |||||
Protection | Battery low voltage alarm | 44VDC(default value) | ||||
Battery low voltage protection | 42VDC(default value) | |||||
Anti-islanding protection | ≤2S | |||||
Overload power protection | Automatic Protection (battery mode),Circuit Breaker or Insurance (AC mode) | |||||
Inverter output short circuit protection | Automatic protection (battery mode),circuit breaker or insurance (AC mode) | |||||
Temperature protection | >90℃(Shut down output) | |||||
Operating temperature | -10℃~50℃ | |||||
Storage temperature | -15℃~60℃ | |||||
Environment | Noise | ≤55dB | ||||
Elevation | 2000m(More than derating) | |||||
Humidity | 0%~95% (No condensation) | |||||
Dimension and Weight | ||||||
Product Size(L*W*Hmm) | 430*325*112.5 | 515*365*117 | 630*540*130 | |||
Package Size(L*W*Hmm) | 510*380*178 | 600*430*192 | 715*605*205 |